Product Code: 177710 | Heatrae Sadia Direct Megaflo D 70 L HE(Reference #177710)
Capacity - 70
High - 809mm Wide - 530mm
Weight Empty - 24kg Weight Full - 124kg
Coil Rating - 5.2kW
Element Rating @ 240v - 1 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£446.02 Ex VAT £524.07 Including VAT at 17.5% |
|
|

Product Code: 177711 | Heatrae Sadia Direct Megaflo DD 125 L HE(Reference #177711)
Capacity - 125
High - 1115mm Wide - 530mm
Weight Empty - 29kg Weight Full - 178kg
Coil Rating - 11.8kW
Element Rating @ 240v - 2 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£518.55 Ex VAT £609.30 Including VAT at 17.5% |
|
|

Product Code: 177712 | Heatrae Sadia Direct Megaflo DD 145 L HE(Reference #177712)
Capacity - 145
High - 1241mm Wide - 530mm
Weight Empty - 31kg Weight Full - 200kg
Coil Rating - 12.5kW
Element Rating @ 240v - 2 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£641.77 Ex VAT £754.08 Including VAT at 17.5% |
|
|

Product Code: 177713 | Heatrae Sadia Direct Megaflo DD 170 L HE(Reference #177713)
Capacity - 170
High - 1398mm Wide - 530mm
Weight Empty - 36kg Weight Full - 230kg
Coil Rating - 14.5kW
Element Rating @ 240v - 2 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£671.72 Ex VAT £789.27 Including VAT at 17.5% |
|
|

Product Code: 177714 | Heatrae Sadia Direct Megaflo DD 210 L HE(Reference #177714)
Capacity - 210
High - 1499mm Wide - 530mm
Weight Empty - 42kg Weight Full - 252kg
Coil Rating - 16.9kW
Element Rating @ 240v - 2 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£715.46 Ex VAT £840.67 Including VAT at 17.5% |
|
|

Product Code: 177715 | Heatrae Sadia Direct Megaflo DD 250 L HE(Reference #177715)
Capacity - 250
High - 1751mm Wide - 530mm
Weight Empty - 49kg Weight Full - 299kg
Coil Rating - 17.4kW
Element Rating @ 240v - 2 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£782.25 Ex VAT £919.14 Including VAT at 17.5% |
|
|

Product Code: 177716 | Heatrae Sadia Direct Megaflo DD 300 L HE(Reference #177716)
Capacity - 300
High - 2065mm Wide - 530mm
Weight Empty - 58kg Weight Full - 358kg
Coil Rating - 18.9kW
Element Rating @ 240v - 2 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£843.27 Ex VAT £990.84 Including VAT at 17.5% |
|
|

Product Code: 177717 | Heatrae Sadia Direct Megaflo DDD 210 L HE(Reference #177717)
Capacity - 210
High - 1499mm Wide - 530mm
Weight Empty - 42kg Weight Full - 252kg
Coil Rating - 16.9kW
Element Rating @ 240v - 3 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£739.49 Ex VAT £868.90 Including VAT at 17.5% |
|
|

Product Code: 177718 | Heatrae Sadia Direct Megaflo DDD 250 L HE(Reference #177718)
Capacity - 250
High - 1751mm Wide - 530mm
Weight Empty - 49kg Weight Full - 299kg
Coil Rating - 17.4kW
Element Rating @ 240v - 3 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£828.30 Ex VAT £973.25 Including VAT at 17.5% |
|
|

Product Code: 177719 | Heatrae Sadia Direct Megaflo DDD 300 L HE(Reference #177719)
Capacity - 300
High - 2065mm Wide - 530mm
Weight Empty - 58kg Weight Full - 358kg
Coil Rating - 18.9kW
Element Rating @ 240v - 3 x 3kW
Click here for Full Information on Megaflo HE Cylinders
£889.33 Ex VAT £1,044.96 Including VAT at 17.5% |
|
Connections: Must be installed by a competent installer in accordance with Local Regulations. England and Wales - Building Regulations G3, Scotland - Technical Standards P3, N. Ireland - Building Regulations P5.
Cold Water Control: 22mm HiFlo cold water combination valve assembly comprising 3 bar pressure reducer, ¼ turn isolating ball valve, line strainer, non-return valve and 8 bar expansion valve. Cold water control valve (3 bar) is supplied for use with mains pressure of 20 bar to 1.5 bar, at the lower pressure, performance will be reduced accordingly. Normal working pressure is 3 bar.
Compatible Boilers: Gas or oil fired sealed system or open vent type, fitted with integral control thermostat.
Electrical: Connection is direct to terminals in the immersion heater which must be permanently connected to the supply through a double-pole linked isolating switch with a minimum breaking capacity of 13A. On indirect models, controls should be wired to the boiler, programmer etc. in accordance with the control scheme being used. All electrical installation must conform to the latest IEE Wiring Regulations.
Fixing: Floor standing only.
Flow Rates: Up to 72 litres per minute depending on adequate supply conditions.
Minimum Water Supply Reqmnts: 20 litres per minute flow and 1.5 bar pressure. (At lesser values, the unit will operate but outlet flow rates may be unacceptable, especially with multiple draw-offs.) Please contact our Specification Advice Team to discuss specific site conditions if the above minimum requirement cannot be met. Tel: 01603 420220.
Plumbing: Inlet/outlet: Use 22mm compression fittings or ¾" bsp male. Indirect coil: Use 22mm compression fittings or ¾" bsp male. ½" T&P relief valve 15mm compression outlet.
Pressure Testing: To 15 bar and batch testing to 30 bar.
Secondary Circulation: Via 22 x 22 x 15mm swept tee (not supplied, available as accessory 95:970:509) Fitted to inlet pipework (circulating pump not supplied).
Tundish: 15mm inlet and 22mm compression outlet.
WaterExpansion: Via air gap built into the top of the cylinder. The patented floating baffle helps maintain the air gap.
|
|